|
|
BBV-1F Flanged 3-valve block manifold
$159.00
-- Flanged 3-valve block manifold
Purchase BBV-1F Flanged 3-valve block manifold
BBV-1F Flanged 3-valve Block Manifold for Dwyer 3100 Series Explosion-Proof Differential Pressure Transmitters.
The series BBV-1 Block Manifold can be
used over a broad range of industrial applications including oil
refineries, nuclear power stations, petrochemical processing, and more.
The Series BBV-1 body is forged from 316 stainless steel bar stock and
designed to withstand repeated open and close operations. Suited to
control oil, water, toxic fluids, chemicals, air, and steam; the 3-valve
block manifold has (2) isolate and (1) equalizing valves. Each valve
stem is precision machined with hard seats to reduce operating torque.
The flanged model is designed to mount to an industrial differential
pressure transmitter. The BBV-1F comes with four 7/16-20 UNF mounting
bolts and two PTFE gaskets, and the BBV-1D comes with eight 7/16-26 UNF
mounting bolts and four PTFE gaskets. Specifications Service: Compatible liquids, gases, or steam.
End Connections:
Process Connection: No flange: 1/2" female NPT; Flange: DIN 19213
flange; Instrument Connection: No flange: 1/2" female NPT; Flange: DIN
19213 flange; Vent/Test: 1/4" female NPT.
Wetted Materials: Body, stem, valve assembly: 316 SS; Stem packing: PTFE.
Pressure Limit: 6000 psi (400 bar).
Temperature Limit: 464°F (240°C).
Other Material: Handle: 304 SS.
Purchase BBV-1F Flanged 3-valve block manifold
Other products in the category Accessories / Dwyer Accessories:
351-9 Dwyer RS-232 to RS-485 converter -- The Mother NodeT Communication Signal Converter line of RS-232 to
RS-485 converters offers an easy way to use virtually any PC to
communicate with half duplex RS-485 devices. Complicated hand-shaking
issues are eliminated with these easy to use
A-201 Tubing for Portable Digital Manometers -- Rubber tubing, 3/16" ID, 9 ft length.
Use with Dwyer hand-held digital manometers: 475, 478A, 477, and 477A.
A-266 Dwyer Digihelic Controller mounting bracket -- Surface mounting bracket. Use with Dwyer DH series digital differential pressure controllers and other Dywer differential pressure instruments
A-286 Panel Mount Flange for Magnehelic Gage --
A-286 Panel Mounting Flange for 4-1/2"
Diameter Dwyer Magnehelic Gages
The new mounting flange can be used on any Dwyer
Instruments, Inc. gage that possesses a 4-1/2" (115 mm) diameter housing.
The flange is
A-298 Flat Flush Mount Bracket for Dwyer Capsuhelic -- Flat aluminum bracket for flush mounting Capsuhelic® gage
A-299 Mounting Bracket for Magnehelic Gage
A-300 Flat Mounting Bracket for Magnehelic Gage
A-301 Static Pressure Tip -- Static pressure tip for 1/4" metal tubing connectionUse with Dwyer Dwyer DH series digital differential pressure controllers and other Dywer differential pressure instruments
A-302 Static Pressure Tip -- Static pressure tip for 3/16" and 1/8"" plastic or rubber tubingUse with Dwyer DH series digital differential pressure controllers and other Dywer differential pressure instruments
A-302F-A Static Pressure Tip -- Static pressure tip with mounting flange, 4" hook style. For 3/16" ID rubber or plastic tubing, includes mounting screwsUse with Dwyer DH series digital differential pressure controllers and other Dywer differential pressure instruments
A-308 Static Pressure Fitting for Magnehelic Gage -- A-308 Static pressure fitting for Dwyer magnehelic gauges. Hose barb Fits 3/16" and 1/8" ID plastic or rubber tubing.
A-309 3-Way Manifold Valve for Dwyer Capsuhelic -- A-309 3-Way Manifold Valve for Dwyer Capsuhelic gage
A-310A 3-Way Valve for Magnehelic Gage
A-314 Bleed Fitting for Dwyer Capsuhelic -- A-314 Bleed Fitting for Dwyer Capsuhelic gage. Affords easier, safer purging of trapped air when using a Capsuhelic® gage with liquids. Also useful for draining condensate when installed in lower ports. To open, simply loosesn the h
A-320-B Static Pressure Tip -- Series A-320 Instrument Enclosure protects instruments in all applications. The weatherproof enclosure is water tight and corrosion resistant. Weatherproof enclosure for 3000MR Photohelic® Switch/Gage, Series 605 Magnehelic® Differential Pressure Tr
A-321 Safety Relief Valve for Magnehelic Gage
A-370 Mounting Bracket for Dwyer Capsuhelic -- A-370 Mounting bracket. First, flush-mount the Capsuhelic® gage in the bracket, then mount the bracket to a vertical surface. Steel with gray
hammertone epoxy finish.
A-402A Zippered Carry Case for Digital Manometers -- Tough gray nylon pouch protects any Series 475, 476A, 478A, 477, 477A or 490 Dwyer Digital Manometer . Double zippered for quick and easy access. With belt loop that snaps closed.
Dimensions: 7-1/2½H x 3½W x 2-1/4½D (191 x 76 x 57
A-432 Portable Kit for Magnehelic Gage
A-438 Dwyer mounting bracket for DHII -- Surface mounting bracket. Use with Dwyer DHII series digital differential pressure controllers.
A-464 Flush Mount Kit for Magnehelic Gage -- The A-464 Mounting Kit provides a flush mounting solution for Magnehelic® gage installations for applications such as clean rooms and mechanical equipment rooms. The A-464 can also be used as an alternative means to flush mount Magnehelic® gages on c
A-471Portable Kit for Dwyer Capsuhelic -- For portable operation, the A-471 Capsuhelic®
Portable Gage Kit is available complete with tough polypropylene carrying case,
mounting bracket, 3-way manifold valve, two 10' high pressure hoses, and all
necessary fittings.
A-480 Plastic Static Pressure Tip -- Plastic static pressure tip for use with DigiMag DM-1000 series pressure and flow gauges.
A-481 Installer Kit -- Installer Kit, includes two plastic static pressure tips and 7 ft PVC tubing for use with DigiMag DM-1000 series pressure and flow gauges.
A-489 Static Pressure Tip -- Straight static pressure tip with flange, in three lengths: Model A-489, 4"Model A-491, 6"Model A-493, 8"Use with Dwyer Dwyer DH series digital differential pressure controllers and other Dywer differential pressure instruments
A-496 Heavy Duty Flush-Mount Bracket for Dwyer Capsuhelic -- A-496 Heavy Duty Flush-Mount Bracket for Dwyer Capsuhelic® gages. Use in high-shock or high vibration applications
A-605 Air Filter Kit for Magnehelic Gage
A-610 Pipe Mounting Kit for Dwyer Gages -- Conplete bracket assembly for permanently mounting Dwyer Magnehelic® and Capsuhelic® gages to pipes from 1-1/4" to 2" diameter.
A-630 SS Angle Bracket -- Stainless steel angle type bracket with stainless steel bolts for mounting Dwyer 3100 series Explosion-Proof Differential Pressure Transmitters.
A-631 SS Flat Bracket -- Stainless steel flat type bracket with stainless steel bolts for mounting Dwyer 3100 series Explosion-Proof Differential Pressure Transmitters.
A-700 Power Supply -- Dwyer A-700 Power Converter User Manual
Model A-700 Power Supply is an economical and reliable power supply suitable for powering all Dwyer pressure, temperature or air
velocity transmitters. Inexpensive, open-frame design allows convenient access
-B Brass Case option for Dwyer Capsuhelic water application -- Brass Case for Dwyer Capsuhelic gage. Required for water and water-based liquids.
BBV-1F Flanged 3-valve block manifold -- BBV-1F Flanged 3-valve Block Manifold for Dwyer 3100 Series Explosion-Proof Differential Pressure Transmitters. The series BBV-1 Block Manifold can be
used over a broad range of industrial applications including oil
refine
BBV-22F Flanged 5-valve block manifold -- BBV-22F Flanged 5-valve Block Manifold for Dwyer 3100 Series Explosion-Proof Differential Pressure Transmitters.
Series BBV-2 Block and Bleed Manifold
is ideal for use over a broad
DIGIHELIC LINKS communication software --
The Digihelic LinksT Communications Software is an easy to use Windows® based program. Data logging and graphing can be set up by the individual control with varying logging periods. Event logging, live inst
DM-1200 Air Flow Option for DigMag Gage -- The airflow option enables the Dwyer DigiMag DM-1000 differential pressure gage to report air velocity and volumentric flow.Air velocity
and flow readings are based upon standard dry air conditions with an ambient
temperature of 70°F and a barometr
HM28-0 1/8" NPT adaptor
HM28-1 Communication software and cable
HM28-2 Universal power adaptor
HM35-1 Communication Software and Cable
HM35-2 Infrared RS232 Serial Adaptor
HM35-3 External Universal Power Adapter.
HM35-PK Gas Pressure Maintenance Kit
HM35-VK Vacuum Pressure Maintenance Kit
MN-1 Dwyer MiniNode RS485 to USB Converter --
MN-1 Signal Converter User Manual
The Model MN-1 Mini-NodeT Communication Signal Converter is a low cost device that converts half duplex RS-485 serial communications signals into a signal that can be read by any computer with a USB port. The integr
NIST Certificate for Dwyer Meters -- N.I.S.T.-traceable certificate of calibration for Dwyer instruments and gages. Lead time 1 to 2 weeks.
NISTCAL-PG1 -- Have your Dwyer Digihelic DH series and DH3 series differential pressure controllers NIST calibrated by Dwyer Instrument's accredited calibration laboratory. Less than 1 week lead time.
-SP LED Setpoint Indicator for Magnehelic Gage -- SP Indicator Product SheetSP Indicator Dimensional Drawing
LED Setpoint Indicator for Dwyer Magnehelic® Gages The bright-red LED located
on the scale face clearly indicates positive, negative or differential pre
Home | Data Loggers | Air Flow / Anemometers | Water Quality Meters | Pressure Meters | Gas Detectors | Accessories | Hygrometers | Thermometers | Moisture Meters | Particle Counters | Air Flow / Tracer Smoke | Vibration Meters | Shop by BRAND | Light Meters | Sound Meters | Tachometers & Strobosopes
Instruments that measure and datalog temperature, humidity, airflow, pressure, gases, light, RPM, pH, weight, water quality, weather
MeterMall USA Shopping Cart Software by Nexternal
|
|